cogvalveفارسی
Condensate manifolds
AI-generated product illustration. Final details are confirmed against the order specification.

Condensate manifolds

3 models in this family

Review the listed models and configurations in this family, then select one for a quotation request.

Selected model

Condensate collection manifold

Condensate collection manifold with a cast-steel body assembled from welded two-tracer modules. Double-piston TCMs valves and reinforced-graphite seals are combined with a removable inverted-bucket steam trap using a universal connector. The main outlet is 1 1/2-inch butt-weld. The 1/2- or 3/4-inch tracer connections can be socket-weld, NPT or butt-weld. The construction designation is ISO PN50 and the maximum temperature is 400°C; the 28-bar pressure limit applies to the arrangement fitted with steam trap 2011.

Selected model specifications

BodyCast steel; welded two-tracer modules
Branch valvesDouble-piston TCMs
SealingReinforced graphite
Steam trapRemovable inverted bucket with universal connector
Main outlet1 1/2 in BW
Tracer connections1/2 or 3/4 in; SW / NPT / BW
Construction designationISO PN50
Maximum temperature400°C
Maximum pressure with trap 201128 bar
Optional equipmentKVMs main isolation, DN40 flange and lower/upstream drains

Models and configurations

Select a configuration. The family image changes only when the model has a distinct illustration.

Condensate collection manifoldBody: Cast steel; welded two-tracer modules · Branch valves: Double-piston TCMs · Sealing: Reinforced graphite · Steam trap: Removable inverted bucket with universal connector · Main outlet: 1 1/2 in BW · Tracer connections: 1/2 or 3/4 in; SW / NPT / BW · Construction designation: ISO PN50 · Maximum temperature: 400°C · Maximum pressure with trap 2011: 28 bar · Optional equipment: KVMs main isolation, DN40 flange and lower/upstream drainsCondensate collection manifold with a cast-steel body assembled from welded two-tracer modules. Double-piston TCMs valves and reinforced-graphite seals are combined with a removable inverted-bucket steam trap using a universal connector. The main outlet is 1 1/2-inch butt-weld. The 1/2- or 3/4-inch tracer connections can be socket-weld, NPT or butt-weld. The construction designation is ISO PN50 and the maximum temperature is 400°C; the 28-bar pressure limit applies to the arrangement fitted with steam trap 2011.
Modular condensate collection manifoldBody: Forged steel; welded four- or six-tracer modules · Branch valves: TCMs · Sealing rings: Reinforced graphite · Trap arrangement: Inverted-bucket trap or PPC1 trap station · Main outlet: 1 1/2 in SW · Tracer and drain connections: 1/2 in SW · Construction designation: ISO PN50 · Maximum temperature: 400°C · Maximum pressure with trap 1811 or 2011: 28 bar · Optional equipment: KVMs main isolation, DN40 flange and thermal insulation blanketModular condensate collection manifold with a forged-steel body made from welded four- or six-tracer modules. TCMs piston valves and reinforced-graphite rings serve the branches. Steam-trap arrangements include an inverted-bucket trap or a PPC1 trap station. The main outlet is 1 1/2-inch socket-weld, with 1/2-inch socket-weld tracer and drain connections. The construction designation is ISO PN50 and the maximum temperature is 400°C. The 28-bar pressure limit applies to configurations fitted with trap 1811 or 2011.
Condensate manifold and trap assemblyBody: Forged steel; welded two-tracer module · Trap station: TVS3100 / TVS3000 · Spare-branch arrangement: One active tracer and one spare branch arrangement · Main outlet: 1 1/2 in SW · Tracer connections: 1/2 in SW on TVS · Drain outlet: 1/2 in SW · Construction designation: ISO PN50 · Maximum temperature: 400°C · Maximum pressure with trap 2011: 28 bar · Optional equipment: TCRd upstream drain, KVMs main isolation and thermal insulationCondensate collection assembly built from welded two-tracer forged-steel modules and fitted with TVS3100 or TVS3000 trap stations. A two-branch module can also be arranged with one active tracer and a spare branch. The main outlet is 1 1/2-inch socket-weld, the tracer connections on the TVS are 1/2-inch socket-weld, and the drain is 1/2-inch socket-weld. The construction designation is ISO PN50 and maximum temperature is 400°C. The 28-bar pressure limit applies with trap 2011; TCRd upstream drains and KVMs main isolation are additional equipment arrangements.