Steam trap stations
AI-generated product illustration. Final details are confirmed against the order specification.

Steam trap stations

2 models in this family

Review the listed models and configurations in this family, then select one for a quotation request.

Selected model

Trap station with two isolation valves

Compact trap station with a carbon-steel body, one Series 2000 stainless-steel inverted-bucket trap and two TCMs piston valves for upstream and downstream isolation. A universal connector allows the trap to be removed and oriented within the assembly. The sealing rings are reinforced graphite. Connections comprise 1/2- or 3/4-inch socket-weld and 1/2-inch NPT. The construction designation is ISO PN50 and maximum temperature is 400°C; the 28-bar pressure limit applies to the arrangement using trap 2011.

Selected model specifications

BodyCarbon steel
Steam trapSeries 2000 stainless-steel inverted bucket
Isolation valvesTwo TCMs piston valves; upstream and downstream
Trap connectionRemovable universal connector
Sealing ringsReinforced graphite
Pipeline connectionsSW 1/2 or 3/4 in; NPT 1/2 in
Construction designationISO PN50
Maximum temperature400°C
Maximum pressure with trap 201128 bar
Optional equipmentTCRd stainless-steel valve for drain, test or decompression

Models and configurations

Select a configuration. The family image changes only when the model has a distinct illustration.

Trap station with two isolation valvesBody: Carbon steel · Steam trap: Series 2000 stainless-steel inverted bucket · Isolation valves: Two TCMs piston valves; upstream and downstream · Trap connection: Removable universal connector · Sealing rings: Reinforced graphite · Pipeline connections: SW 1/2 or 3/4 in; NPT 1/2 in · Construction designation: ISO PN50 · Maximum temperature: 400°C · Maximum pressure with trap 2011: 28 bar · Optional equipment: TCRd stainless-steel valve for drain, test or decompressionCompact trap station with a carbon-steel body, one Series 2000 stainless-steel inverted-bucket trap and two TCMs piston valves for upstream and downstream isolation. A universal connector allows the trap to be removed and oriented within the assembly. The sealing rings are reinforced graphite. Connections comprise 1/2- or 3/4-inch socket-weld and 1/2-inch NPT. The construction designation is ISO PN50 and maximum temperature is 400°C; the 28-bar pressure limit applies to the arrangement using trap 2011.
Trap station with one isolation valveBody: Forged steel · Steam trap: Series 2000 stainless-steel inverted bucket · Main isolation valve: One upstream TCMs piston valve · Sealing rings: Reinforced graphite · Pipeline connections: SW 1/2 or 3/4 in; NPT 1/2 in · Construction designation: ISO PN50 · Maximum temperature: 400°C · Maximum pressure with trap 2011: 28 bar · Optional equipment: TCRd stainless-steel upstream drain or test/decompression valveCompact trap station with a forged-steel body, one Series 2000 stainless-steel inverted-bucket trap and one TCMs piston valve for upstream isolation. This arrangement has one principal isolation valve, using reinforced-graphite sealing rings. Pipeline connections can be 1/2- or 3/4-inch socket-weld, or 1/2-inch NPT. The construction designation is ISO PN50 and maximum temperature is 400°C; the 28-bar pressure limit applies with trap 2011. TCRd stainless-steel upstream drain or test/decompression valves are additional equipment arrangements.